9. Vision/Dri-Tek Dryer Operation

66

PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual

Continuous Flow Drying Mode Using Regulation of
Moisture: 5 MR SP

Full Heat Continuous Flow Operation

This section begins with

Step 7

and it is assumed that

Step 1

through

Step 6

in the start-up procedure

described on

Page 58

have been completed. For this operation procedure we will say that incoming grain

moisture content is 25% and ten points of moisture removal is our goal.

7. Touch the Setup button at the bottom of the Default Operation Screen. Once the “Select Hardware

Setup Parameter to Modify” Screen is displayed, touch the Drying Mode button. When the “Drying
Mode Selection” window appears, touch the Continuous Flow button to select continuous flow drying
mode. Then, touch the Accept/Exit button and return to the “Select Hardware Setup Parameter to
Modify” Screen.

8. Touch the M/C Setup button. When the “Moisture Control Selection” window appears select the

REGULATION OF MOISTURE: 5 SP MR moisture control option. The 5 SP MR cannot be disabled
when operating in this moisture control mode.

Figure 9J

9. Press the 5 SPD Setup button. When the bracketed 5 Speed moisture control setup is displayed

touch the Select Defaults button. Select the Accept/Exit button to save these settings in the computer
and return to the Default Operation Screen.