Power supply for 1, All stack specifications (continued), Specifications – Grain Systems PNEG-1702 User Manual

Page 36

Advertising
background image

5. Specifications

36

PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual

All Stack Specifications (Continued)

14'

18'

20'

22'

26'

Total Holding Capacity (Bushels)

1074

1381

1534

1688

1995

Grain Column Holding Capacity (Bushels)

1022

1314

1460

1606

1898

Fans

28" 10-13 HP

40" 15 HP

36" 10-13 HP

42" 20 HP

36" 15 HP
42" 25 HP

36" 15 HP
42" 30 HP

40" 25 HP
42" 40 HP

Top Auger

8" Dia. 5 HP

8" Dia. 5 HP 8" Dia. 7.5 HP 8" Dia. 7.5 HP 8" Dia. 10 HP

Capacity (BHP)

3800

3800

3800

3800

3800

Bottom Auger

8" Dia. 5 HP

8" Dia. 5 HP 8" Dia. 7.5 HP 8" Dia. 7.5 HP 8" Dia. 10 HP

Meter Roll Drive

SCR, 1/3 HP SCR, 1/3 HP

SCR, 1/3 HP

SCR, 1/3 HP

SCR, 1/3 HP

Capacity - Maximum Rate¹ (BHP)

1960

2520

2800

3080

3640

Electrical Load (Fans, Top and Bottom Augers

²

)

1 Phase, 220 Volt

304

-

-

-

-

3 Phase, 220 Volt

160

182

246

266

384

3 Phase, 440 Volt

80

91

123

133

192

3 Phase, 575 Volt

64

73

98

106

154

1

Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate.

2

Excludes auxiliary load and unload conveyor equipment.

14'

18'

20'

22'

26'

Total Holding Capacity (Bushels)

1074

1381

1534

1688

1995

Grain Column Holding Capacity (Bushels)

1022

1314

1460

1606

1898

Fans

28" 10-13 HP 36" 10-13 HP

36" 15 HP

36" 15 HP

40" 25 HP

Top Auger

8" Dia. 5 HP

8" Dia. 5 HP 8" Dia. 7.5 HP 8" Dia. 7.5 HP 8" Dia. 10 HP

Capacity (BHP)

3800

3800

3800

3800

3800

Bottom Auger

8" Dia. 5 HP

8" Dia. 5 HP 8" Dia. 7.5 HP 8" Dia. 7.5 HP 8" Dia. 10 HP

Meter Roll Drive

SCR, 1/3 HP SCR, 1/3 HP

SCR, 1/3 HP

SCR, 1/3 HP

SCR, 1/3 HP

Capacity - Maximum Rate¹ (BHP)

1960

2520

2800

3080

3640

Electrical Load (Fans, Top and Bottom Augers

²

)

1 Phase, 220 Volt

340

340

-

-

-

3 Phase, 220 Volt

194

194

274

274

436

3 Phase, 440 Volt

97

97

137

137

218

3 Phase, 575 Volt

78

78

110

110

174

1

Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate.

2

Excludes auxiliary load and unload conveyor equipment.