5. Specifications

PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual

39

Stack Dryer Foundation Specifications

Minimum soil bearing capacity = 2000 PSF.

Concrete specifications:

Compressive strength at 28 days - 4000 PSI.

Minimum cement content - 6 sacks/yard.

Maximum slump - 4" ± 1".

Stack Dryer Foundation

Basket Length

14

18

20

22

26

Concrete Pad Size (12' x “X”)

¹

12 x 24

12 x 28

12 x 30

12 x 32

12 x 36

Concrete (Cubic Yards)

20-3/4

24-1/4

26

27-1/2

31

#4 Rebar (Feet)

²

900

1060

1140

1220

1400

Anchors

3

16

20

22

24

28

1

10" Depth with 36" wide x 36" deep footings along each side.

2

#4 Reinforcing rods on 1"-0" centers. Both directions in slab and bottom of footing.

3

Use 3/4" x 9-5/8" minimum anchors with epoxy. GSI part #: Anchor (GTC-0003) epoxy (GTC-0004).