Vision/dri-tek dryer operation – Grain Systems PNEG-1702 User Manual

Page 61

Advertising
background image

9. Vision/Dri-Tek Dryer Operation

PNEG-1702 ETL Listed GSI/FFI Portable Dryer Manual

61

Figure 9C

19. With the Unload Auger switch in the AUTO position, the moisture control is active. Select the

M/C button at the bottom of the Default Operation Screen. When the “Modify Temperature Setpoint”
window appears, set the temperature to approximately 105°F. Let the dryer run on these settings
before adjusting moisture or meter roll settings. These settings will not dry the grain exactly as
desired, but they will serve as a good starting point. A slightly different moisture at the bottom of the
storage bin is not usually a problem as long as full floor aeration is present.

Figure 9D

20. After the run time in

Step 19

, adjust the moisture control and the meter roll speeds if required. Each

time the moisture control is adjusted, it will take approximately the amount time shown in the drying
charts to see the results of this adjustment. For every 5° change in temperature, moisture will
changed by one point.

Advertising