7.5

Electricity (Inverter)

7.5.1 Technical data – D2S INVERTER

Table 3. Technical Data for D2S Inverter

Power class

002

Power (kVA) at 400V

3.5

Output current In (A)

5.0

Max. current 1min (A)

7.6

Overload ability

1.5 x In, 1min/10min

Max. output voltage

Equals to supply voltage

Supply

Supply voltage

380-415Vac (M) or 440-480Vac (C)

Allowable voltage fluctuation

+/- 10%

Nominal supply frequency

50/60Hz +/- 5%

Signal input levels

Digital controls

S1, S2, DID3, DID4, DID5: 42 … 240Vac; 15mA

Control features

Control method

Open loop vector control

Frequency control range

0 ... 250Hz

Frequency command

Electronic potentiometer, 2-step controller or 0 … 10V analog signal

Limit switch functions

Stop limit inputs for both directions

Speed control range

s

N

... 100% (s

N

= motor nominal slip)

Speed accuracy

1% of nominal speed at speed range 10 ... 100%

1/3 of motor nominal slip at speed below 10%

Braking torque

150%

Protections

Motor overload protection

Thermistor or Klixon thermostat based temperature measurement

Overload protection

Fault is detected if the current momentarily exceeds 280% of rated current

Undervoltage / blown fuse

Fault is detected if DC voltage drops below 333V

Overvoltage protection

Fault is detected if DC voltage exceeds 911V

Momentary power loss

Immediate fault stop

Inverter overtemperature

Temperature sensor on the heat sink

Ground fault

Provided by electronic circuitry

Ambient conditions

Ambient temperature

-10°C ... +50°C (14°F ... 122°F) for ED°40%

Storage temperature

-40°C ... +70°C (-31°F ... 158°F) dry

Humidity

<95%RH (no condensation)

Altitude

Maximum 1000m at In. Above 1000m: In reduces 1% per each 100m.

Above 3000m: consult factory.

Vibration

Operation: maximum displacement amplitude 3mm at 2-9Hz.

Maximum acceleration amplitude 0.5g (5m/s²) at 9-200Hz