7.5.7 Parameter adjustments

7.5.7.1 The display panel

Figure 15. Display Panel

The display panel is used for :

Displaying the drive identification, electrical values,
operating or fault parameters

Altering the parameter settings

START

STOP

enter

reset

Drive status indications:

Motor is running, blinks when ramping down.

Direction of motor rotation.

Motor is not running.

Power is on. In case of a fault, the symbol will not light up.

Drive is running outside of certain limit.

Fault is active

Control place indications:

I/O term

I/O-terminals are the selected control place

Keypad

Keypad is the selected control place (not used)

Bus/Comm

Control through Profibus is selected (not used)

Button description

Browse the main menu and the pages of submenus
Edit values

Move in menu
Move cursor
Enter and exit edit mode

START

Start button

STOP

Stop button

Active faults reset
Fault history reset
Confirmation of selections

enter

reset

Advertising