2 parameter descriptions – R&M Materials Handling ELECTRIC CHAIN HOISTS LoadMate Chain Hoist LM 10 Stepless User Manual

Page 39

Advertising
background image

LM10 STEPLESS I&M MANUAL/EN/11.30.2010


39/99

This document and the information contained herein, is the exclusive property of R&M Materials Handling, Inc., and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M Materials Handling, Inc.
Copyright © (2010) R&M Materials Handling, Inc. All rights reserved.

7.5.9 Parameter descriptions

7.5.9.1 General Description

Parameters are assorted to Groups. All Groups are not always listed in control panel. Groups are
shown in the control panel according to password level and selected functions. This feature makes
the viewable parameter menu simple and only needed parameters are shown.

Letter front of the code number describes variable type.

P =

Parameter

V

=

Value

F

=

Active Fault

G =

Group

M

=

Menu

H

=

Fault History

S

=

System

7.5.9.2 Parameter descriptions

Table 11. Parameter Setting and Descriptions

P1 Parameters

G 1.1 General Parameters

Code

Name

Min

Max

Unit

Description

P1.1.1

Password

0

9999

P1.1.2

Acceleration Time

0.0

20.0

s

Time it will take to accelerate from zero to the set maximum frequency

P1.1.3

Deceleration Time

0.0

20.0

s

Time it will take to decelerate from max frequency to zero.

P1.1.4

Minimum Freq

0.00

Max freq Hz

The set minimum operating frequency.

P1.1.5

Maximum Freq

Min freq 120.00

Hz

The maximum frequency may not be higher than the motor nominal frequency
for listed motors.

P1.1.6

Reverse Plugging

50

100

%

See Chapter "Reverse plugging"

P1.1.7

Stop Function

0

1

Stopping mode selection
0 = Brake
1 = Ramping, default
Ramping: When the drive command is switched off the motion is stopped
according to the set deceleration ramp.
Brake: When the drive command is switched off the motor current is cut off,
then the motion is stopped by the mechanical brake.

P1.1.8

MSFreq2/Slowdown 0

100

%

Slowdown frequency and Multistep frequency2,

Setting “100%” equals maximum frequency,

if the setting is lower than minimum frequency then it equals the
minimum frequency

P1.1.9

Multistep Freq 3

0

100

%

3

rd

preset speed.

Setting “100%” equals maximum frequency,

if the setting is lower than minimum frequency then it equals the
minimum frequency

P1.1.10 Multistep Freq 4

0

100

%

4

th

preset speed.

Setting “100%” equals maximum frequency,

if the setting is lower than minimum frequency then it equals the
minimum frequency

P1.1.11 Input set

0

7

Control mode selection, see Chapter "control methods"
0 = MS2 (stop-limit)
1 = MS2/MS3 (slow-limit)
2 = EP2 (stop-limit)
3 = EP2 (slow-limit)
4 = EP3
5 = MS4
6 = MS5
7 = AU (Ain)

Advertising