Crown Audio IQ-MSD Turbo Software User Manual

Page 195

Advertising
background image

IQ–MSD Turbo 1.4 Advanced IQ System Software

Page 195

11 Configuring & Monitoring

System & Load Monitors

An IQ System & Load Monitor such as the SLM-8 provides an IQ System with the capability to monitor the
impedance response of loudspeakers or most any amplifier load and the ability to measure the frequency
response of any line-level or high-level audio output in the system. Once configured, this powerful diagnostic
ability can also operate in a stand-alone mode via the indicators on the front panel of the SLM-8. (See the SLM-
8 Reference Manual
for more details.)

11.1 Initializing an SLM-8 Control Block

The first step in initializing an SLM-8 control block (shown below in Figure 11.1) is to set the IQ address and Crown
Bus loop number. This is normally done automatically during a roll call. However, you can set them manually if you
need to configure a system off-line.

S

M

A

R

T

L

O

A

D

M O N I

T

O

R

Fig. 11.1 An SLM-8 Control Block Screen

IQ Address & Crown Bus Loop: The IQ address number you enter must match the physical IQ address
switch setting on the SLM-8. The Crown Bus loop number must match the physical loop to which the SLM-8 is
wired.

On Line: The phrase “On Line” will appear in the upper right corner of the information area when an SLM-8
is actively connected to and in communication with the IQ System.

Model, Location & Purpose: These three text lines are available for you to include relevant notes about
the unit. Up to 15 characters can be entered on each line.

Advertising