IQ–MSD Turbo 1.4 Advanced IQ System Software

Page 28

2

System AUX: This control opens the System AUX Setup screen, a second type of Control Panel screen. The
system AUX feature allows an external logic signal sensed by the AUX port of an IQ component to cause the IQ
System
settings to be either loaded (engaged) from a specified dataframe file or saved to a specified dataframe
file.

The System AUX Setup screen is shown below in Figure 2.13. The keyboard shortcut to it from the main Control
Panel screen is

A

+

a.

Fig. 2.13 System AUX Setup Screen

Up to 16 different AUX ports can be monitored at the same time and each one can load or save the settings from/
to a different dataframe file. Notice that three parameters are used to define a single System AUX function: Monitor,
Action and Dataframe. Use

Q R Z Y

to select the function you want to enter or edit (

T

does not work in this

screen).

The monitor parameter identifies which AUX port is to be monitored. Use the following procedure to describe
it:

1 Begin with “

L

” followed by the loop number of the IQ component.

2 Use one of the following three-letter mnemonics for the component type:

AMP

Amplifier with IQ–P.I.P.–AP (version 1.45 or later)

MPX

MPX-6 mixer

SMX

SMX-6 mixer

AMB

AMB-5 mixer

MRX

MRX-24 or MRX-12 matrixer

DRN

DRN-16 drone

PSI

Pocket Serial Interface

SLM

SLM-8 system and load monitor