5 pads – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 260

GEI-100332Ga
——— FUNCTION DESCRIPTION ———
6
132
6.15.5 pads
The pads are used for the data exchange among the several components of a Bus system. They can be compared
to the variables of a PLC. The figure 6.15.5.1 shows the overall structure of the system. With the help of pads it
is possible for example to send information from a field Bus to an option card. All the pads can be written and
read. See the several access possibilities in section 10, “Parameter list”
SPEC FUNCTIONS
Pad Parameters
[503]
Pad 0
[504]
Pad 1
[505]
Pad 2
[506]
Pad 3
[507]
Pad 4
[508]
Pad 5
[509]
Pad 6
[510]
Pad 7
[511]
Pad 8
[512]
Pad 9
[513]
Pad 10
[514]
Pad 11
[515]
Pad 12
[516]
Pad 13
[517]
Pad 14
[518]
Pad 15
[519]
Bitword pad A
[536]
Bitword pad B
Parameter description
No.
Value
Standard
Configuration
min
max
Factory
American
Factory
European
Pad 0
503
-32768
+32767
0
0
*, **
Pad 1
504
-32768
+32767
0
0
*, **
Pad 2
505
-32768
+32767
0
0
*
Pad 3
506
-32768
+32767
0
0
*
Pad 4
507
-32768
+32767
0
0
**
Pad 5
508
-32768
+32767
0
0
**
Pad 6
509
-32768
+32767
0
0
-
Pad 7
510
-32768
+32767
0
0
-
Pad 8
511
-32768
+32767
0
0
-
Pad 9
512
-32768
+32767
0
0
-
Pad 10
513
-32768
+32767
0
0
-
Pad 11
514
-32768
+32767
0
0
-
Pad 12
515
-32768
+32767
0
0
-
Pad 13
516
-32768
+32767
0
0
-
Pad 14
517
-32768
+32767
0
0
-
Pad 15
518
-32768
+32767
0
0
-
Bitword pad A
519
0
65535
0
0
***, ****
Pad A Bit 0
520
0
1
0
0
***, ****
Pad A Bit 1
521
0
1
0
0
***, ****
Pad A Bit 2
522
0
1
0
0
***, ****