GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 416

GEI-100332Ga
——— PARAMETER LISTS ———
10
22
Parameter
No.
Format
Value
Access via
min
max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Inversion out 3
Enabled
Disabled
1269
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Digital output 4
(Select like output 1)
148
U16
0
77
Overld
avail. (6)
Overld
avail. (6)
ü
R/Z
-
-
Inversion out 4
Enabled
Disabled
1270
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Digital output 5
(Select like output 1)
149
U16
0
77
Curr lim.
state (4)
Curr lim.
state (4)
ü
R/Z
-
-
Inversion out 5
Enabled
Disabled
1271
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Digital output 6
(Select like output 1)
150
U16
0
77
Over-
voltage
(12)
Over-
voltage
(12)
ü
R/Z
-
-
Inversion out 6
Enabled
Disabled
1272
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Digital output 7
(Select like output 1)
151
U16
0
77
Under-
voltage
(11)
Under-
voltage
(11)
ü
R/Z
-
-
Inversion out 7
Enabled
Disabled
1273
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Digital output 8
(Select like output 1)
152
U16
0
77
Over-cur-
rent (14)
Over-cur-
rent (14)
ü
R/Z
-
-
Inversion out 8
Enabled
Disabled
1274
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Relay 2
(Select like output 1)
629
U16
0
77
Stop ctrl
(23)
Stop ctrl
(23)
ü
R/Z
-
-
Inversion relay 2
Enabled
Disabled
1275
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-