GEI-100332Ga
——— PARAMETER LISTS ———
10
54
Parameter
No.
Format
Value
Access via
min
max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Latch
ON
OFF
633
U16
0
1
ON
ON
ü
R/Z
1
0
-
-
Activity
Ignore
Warning
Disable drive
Quick stop
Normal stop
Curr lim stop
634
U16
0
5
Disable
drive
Disable
drive
ü
R/Z
0
1
2
3
4
5
-
-
Ok relay open
ON
OFF
635
I16
0
1
ON
ON
ü
R/W
1
0
-
-
Hold off time [ms]
636
U16
0
10000
0
0
ü
R/W
-
-
Restart time [ms]
637
U16
0
10000
0
0
ü
R/W
-
-
Activity
Disable drive
Quick stop
Normal stop
Curr lim stop
639
U16
0
5
Disable
drive
Disable
drive
ü
R/Z
2
3
4
5
-
-
Ok relay open
ON
OFF
640
I16
0
1
ON
ON
ü
R/W
1
0
-
-
Encoder 1 state
Encoder Fault
Encoder ok
648
U16
0
1
-
R
0
1
QD
R
0
1
Refresh enc 1
(Enc 1 loss detect)
Enabled
Disabled
649
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Encoder 2 state
Encoder Fault
Encoder ok
651
U16
0
1
-
R
0
1
QD
R
0
1
Refresh enc 2
(Enc 2 loss detect)
Enabled
Disabled
652
U16
0
1
Disabled
(0)
Disabled
(0)
ü
R/W
1
0
-
-
Motor I2t accum
655
Float
0,00
100,00
-
-
ü
R
-
-
Acc delta speed0 [FF]
659
U32
0
232-1
100
100
ü
R/W
-
-
Acc delta time 0 [s]
660
U16
0
65535
1
1
ü
R/W
-
-
Dec delta speed0 [FF]
661
U32
0
232-1
100
100
ü
R/W
-
-
Dec delta time 0 [s]
662
U16
0
65535
1
1
ü
R/W
-
-
S acc t const [ms]
663
Float
100
3000
300
300
ü
R/W
-
-
S dec t const [ms]
664
Float
100
3000
300
300
ü
R/W
-
-
S acc t const 0 [ms]
665
Float
100
3000
300
300
ü
R/W
-
-
S dec t const 0 [ms]
666
Float
100
3000
300
300
ü
R/W
-
-
S acc t const 1 [ms]
667
Float
100
3000
300
300
ü
R/W
-
-
S dec t const 1 [ms]
668
Float
100
3000
300
300
ü
R/W
-
-
S acc t const 2 [ms]
669
Float
100
3000
300
300
ü
R/W
-
-
S dec t const 2 [ms]
670
Float
100
3000
300
300
ü
R/W
-
-
S acc t const 3 [ms]
671
Float
100
3000
300
300
ü
R/W
-
-
S dec t const 3 [ms]
672
Float
100
3000
300
300
ü
R/W
-
-
Fwd-Rev
No direction
Fwd direction
Rev direction
No direction
673
U16
0
3
1
1
ü
R/W
0
1
2
3
ID
R/W
0
1
2
3