Table 9. Troubleshooting

Problem

Suggested Action

LEDs
SYSTEM LED does

not light up after the

switch is turned on.

Verify if the power cord is securely connected to the switch

and a wall socket/power strip.

RPS LED does not light

up after a redundant

power supply is attached.

1. Verify if the RPS cable is securely connected to the

RPS connector and a wall socket/power strip.
2. Make sure that the RPS meets with the standards

provided in the RPS section.

FAN LED is

amber blinking

Check the fans on the back of the switch. If any of the

fans is defective, refer to section 7.2 to replace the fan.

Ethernet Link LED

does not illuminate

after an Ethernet

cable is attached.

1.Verify if the Ethernet cable is securely connected to your

LAN switch/hub/PC and to the switch. Make sure the PC

and/or hub/switch is turned on.
2.Verify if your cable is sufficient for your network

requirements. A 1000 Mbps network (1000BaseTx)

should use cables labeled Cat 5. 10Mbit/sec

cables may tolerate lower quality cables.

Network Access
PC cannot access

another host in the

same network

1.Check the Ethernet cabling is good and the LED is green.
2.If the port LED is amber, check if this port is disabled.

You may experience a disconnected network in a short

period (around 1 minute) if you just turned on the STP.