3. Orient the motor conduit box in the required

position. Align the motor mounting holes with the

mating tapped holes on the discharge head. Lower

the motor until the registers engage and the motor

rests on the discharge head. Secure motor with

capscrews provided.

4. On drivers having a non-reverse ratchet or pins,

manually turn the driver shaft clockwise viewed

from the top until the non-reverse ratchet or pins

fully engage.

5. Lubricate motor bearings in accordance with

instructions given on lubrication plate attached to

the motor case.

NOTE: Please read and follow the motor manufacturer’s

instructions before lubricating the motor

bearings. Too much lubricant can cause the

bearings to overheat and prematurely fail.

The motor must not be tested for direction

of rotation when coupled to the pump.

If pump should rotate in the wrong direction, serious

damage to the pump and motor would result. Also

serious injury to personnel could result.
6. Make temporary electrical connections according

to tagged leads or diagram attached to the motor.

Motor must rotate counter-clockwise when viewed

from the top. See arrow on pump name plate. If

motor does not rotate counter-clockwise, you can

change the rotation by interchanging any two leads

(For three phase only, for single phase motors see

motor manufacturer’s instructions.)

7. Motor shaft end play adjustment: if required,

motor shaft end play shall be checked with a dial

indicator prior to connecting the pump coupling to

the solid shaft motor. Consult the applicable motor

manufacturer’s instruction manual for detailed

information on motor shaft end play.

COUPLING INSTALLATION:

(SEE FIGURES 14 and 15)

1. Check all mating face with a fine flat file before

installation. Remove all burrs from face.

2. Apply a thin film of oil on the pump key (730) and

insert key into headshaft keyway seat.

3. Gently lower pump hub of coupling (614) onto

headshaft.

4. Thread on the adjusting plate (613) onto the

headshaft until flush with top of the headshaft.

5. Clean driver shaft by removing all grease and burrs.

Try to fit the key on the driver hub (610) before

installing it to the driver shaft.

Figure 14

Figure 15

6. Apply a thin film of oil to the driver key (730) and

insert key into drive shaft keyway seat. Place the

driver hub (610) onto the drive shaft and with key

slide it up the drive shaft until the annular grove is

exposed. Install split ring (722) in the groove and

slide driver hub down over the split ring to capture it.

7. If the pump is supplied with an adjustable spacer

coupling (see Figure 15), install spacer (612) between

headshaft and driveshaft hubs. Secure with capscrews

(759) and hex nuts (735).