Fault finding chart – Xylem FH SH User Manual

Page 23

Advertising
background image

23

en

8. Fault finding chart

PROBLEM

PROBABLE CAUSE

POSSIBLE REMEDIES

A) No electrical power
B) Blown fuses:

B1 Because inadeguate (blowing cur-

rent too low)

B2 Because the motor or the supply

cable are damaged

C) Overload protection previously

tripped

A) The rotating part is partially or complete-

ly obstructed (generally the impeller is
obstructed by foreign objects)

B) The pump is not primed: inadequate filling

or defective suction pipe or foot valve seal
(Warning! The mechanical seal could
have suffered serious damage)

C) Excessive suction lift and/or flow re-

sistance in the suction pipe

D) Wrong direction of rotation

A) The pump is cavitating

B) Motor bearings worn out
C) Foreign objects between the fixed

and rotating parts

A) See 3C
B) Momentary loss of a phase
C) Incorrect setting
D) The pump’s delivery is higher than the

rated one

E) Dense and viscous liquid

A) Supply electrical power

B1 Replace fuses with adequate ones
B2 Repair the motor or replace the cable

C)Reset the protection (if it trips again

see problem 4)

A) Dismantle the pump and clean it

B) Fill the pump with liquid after having

checked the seal of the suction pipe
and foot valve. Also check the in-
tegrity of the mechanical seal

C) - Reduce the suction lift.

- Use a larger diameter pipe.
- Flush the foot valve.
- Replace the foot valve with a big-

ger one

D) Switch two leads in the terminal

board or starter

A) - Choke the delivery

- See 2C

B) Replace the bearings
C) See 2A

C) Set to rated current
D) Close the delivery valve until the ca-

pacity returns to the rated value

E) Determine the actual power require-

ments and replace the motor ac-
cordingly

1. The pump

doesn’t start

2. Insufficient

or

no delivery

3. The pump vibra-

tes and is too
noisy

4. Overload protec-

tion trips:
– accidentaly

– systematically