5 maintenance and cleaning, 1 maintenance, 2 sensor cleaning – YSI NiCaVis 701 IQ NI User Manual

Page 39: 1 cleaning agents and accessories, Maintenance and cleaning -1, 1 maintenance -1 5.2 sensor cleaning -1, Cleaning agents and accessories -1, 5maintenance and cleaning

Advertising
background image

NiCaVis 70x IQ NI

Maintenance and cleaning

5 - 1

ba76132e01

03/2013

5

Maintenance and cleaning

5.1

Maintenance

The UV NiCaVis 70x IQ NI sensor operates maintenance-free.

5.2

Sensor cleaning

5.2.1 Cleaning agents and accessories

Cleaning agents

To clean the sensor, use the following cleaning agents only:

* For the final cleaning prior to a

Sensor check

or

Zero adjustment

, only

use cleaning agents with purity grade "for analysis". Finally, thoroughly

rinse the sensor with ultrapure water.

Accessories

Sponge

Plastic-bristled brushes of different sizes.

Interdental brushes are suitable for the cleaning of the compressed

air channels.

Flocked cleaning cards (see accessories)

Lens tissues

Wash bottle

Note
Never use any pressure washer, steam blaster, abrasives or metal
brushes to clean the sensor. Risk of damaging the sensor.

Contamination

Cleaning agents

Water-soluble substances

– Primary cleaning: Tapwater,

warm if possible

(30 - 50 °C)

– Precision cleaning: House-

hold washing-up liquid + ultra-

pure water.

Lime deposits

5 % hydrochloric acid *

Grease deposits

Mixture of isopropanol and water

(approx. 70 % isopropanol) *

Advertising
This manual is related to the following products: