Power, Front panel configuration port, Power -8 – Extron Electronics Fiber Matrix 6400 User Manual
Page 24: Installation, cont’d

Installation, cont’d
Fiber Matrix 6400 Switcher • Installation
2-8
Power
f
Primary and Redundant AC power connectors — Plug standard IEC power
cords into these connector to connect the switcher to 100 VAC to 240 VAC,
50-60 Hz power sources.
N
For the most reliable power, connect the Redundant power cord to either
an uninterruptible power source or to a power source that is completely
independent from the primary power source.
g
Primary and Redundant power supply indicator LEDs —
Green —
Indicates that the associated power supply is operating within
normal tolerances.
Red —
Indicates that the associated power supply is operating outside
the normal tolerances or has failed. See chapter 7, “Maintenance and
Modifications“ to replace the power supply.
Front Panel Configuration Port
FIBER MATRIX 6400
CONTROL
CONFIG
ENTER
PRESET
VIEW
ESC
FIBER OPTIC DIGITAL MATRIX SWITCHER
POWER SUPPLY
PRIMARY
REDUNDANT
1
Figure 2-6 — Front panel configuration port
a
Configuration port — This 2.5 mm mini stereo jack serves the same serial
communications function as the rear panel Remote port, but it is easier
to access than the rear port after the matrix switcher has been installed
and cabled. The optional 9-pin D to 2.5 mm mini jack TRS RS-232 cable,
part #70-335-01 (figure 2-7), can be used for this connection.
6 feet
(1.8 m)
Part #
70-335-01
5
1
9
6
Sleeve (Gnd)
Ring
Tip
9-pin D
Connection
TRS Plug
Pin 2
Computer's RX line
Tip
Pin 3
Computer's TX line
Ring
Pin 5
Computer's signal ground
Sleeve
Figure 2-7 — Optional 9-pin TRS RS-232 cable