Programmer’s Guide, cont’d

Fiber Matrix 6400 Switcher • Programmer’s Guide

4-12

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

Save, recall, and directly write presets (continued)

Read room outputs

EX*

MR

}

X1)

,

X#

1

,X#

2

,

...

X#

n

]

Example:

E

3MR

}

Class 1,01,02,08,09

]

Outputs 1, 2, 8, and 9 are
assigned to room 3, which
named “Class 1”.

Recall room preset

X*

*

X(.

Rmm

X*•

Rpr

X(]

Command character is a
period.

Directly write a room
preset

E

+

X*

*

X(

P

X@

*

X#

!

X@

*

X#

%

X@

*

X#

$ ...

X@

*

X#

!

}

Enter as many ties as are
valid for this configuration.
The ! tie command, & tie,
and % tie commands are all
valid and equivalent.

Rmm

X*•

Spr

X(]

Example:

+7*3P12*7&11*5&4*5%6*6!

Esc

Brackets are shown to
separate ties for clarity only.
Create preset 3 for room 7,
which ties input 12 to output 7,
input 11 to output 5, input
4 to output 5, and input 6 to
output 6.

Rmm07

Spr03

]

View ties, mutes, and presets

View output tie

X#

&

X@]

Example:

15&

27

]

Input 27 is tied to output 15.

View output tie

X#

%

X@]

Example:

7%

02

]

Input 2 is tied to output 7.

View output mutes

E

VM

}

X$

1

,

X$

2

, ...

X$

n

]

Each

X$

response is the mute

status of an output, starting
from output 1. n is the
highest-numbered output.

N

X@

= Input number

00 – 64 (00 = untied)

X#

= Output number

01 – 64

X$

= Mute

0 = not muted, 1 = muted

X*

= Room # (for room presets)

10 max. (Each can have up to 10 presets (

X(

) assigned.)

X(

= Room preset #

00 – 10 (00 = current configuration for room)

X1)

= Name

12 characters maximum for input and output names