Performing soft system resets (resets 3, 4, and 5) – Extron Electronics Fiber Matrix 6400 User Manual

Page 55

Advertising
background image

3-29

Fiber Matrix 6400 Switcher • Operation

Performing soft system resets (resets 3, 4, and 5)

Perform a soft reset of the switcher as follows:

1

.

Use an Extron Tweeker or other small screwdriver to press and hold the rear

panel Reset button until the rear panel Reset LED and the front panel View

and Esc buttons blink once (events reset), twice (system reset), or three times

(absolute reset).

Release, then immediately
press and release again.

RESET

RESET

RESET

CONTROL

T

VIEW

ESC

CONTROL

T

VIEW

ESC

CONTROL

T

VIEW

ESC

Release, then immediately
press and release again.

6 seconds

9 seconds

Press and hold
the Reset button.

3 seconds

View and Esc buttons flash once.

Reset LED flashes once.

Release, then immediately
press and release again.

Reset LED flashes twice.

Press and hold
the Reset button.

Press and hold
the Reset button.

Reset LED flashes

three times.

View and Esc buttons flash twice.

View and Esc buttons flash three times.

IP Settings

Reset

Absolute
Reset

Events

Reset

2

.

Release the Reset button and then immediately press and release the Reset

button again. Nothing happens if the second momentary press does not occur

within 1 second.