IPL 250 • Hardware Features and Installation

2-4

Hardware Features and Installation

Optional rack shelves and an assortment of mounting kits (back of the rack,

furniture, and projector pole mount) are available for use with the IPL. See

appendix A

for part numbers of these accessories, and read the instructions that

come with the rack shelf or mounting kit for installation procedures.
The IPL 250 includes rubber feet so it can be set on a table. If you are going to

mount the unit to a rack, rack shelf, furniture, or pole, and these feet were attached

to the enclosure, remove the feet before mounting.

Rack mounting

UL rack mounting guidelines

The following

Underwriters Laboratories (UL)

guidelines pertain to the safe

installation of the IPL 250 in a rack.

1.

Elevated operating ambient temperature

— If installed in a closed or

multi-unit rack assembly, the operating ambient temperature of the rack

environment may be greater than room ambient temperature. Therefore,

install the IPL in an environment compatible with the maximum ambient

temperature (Tma = +122 °F, +50 °C) specified by Extron.

2.

Reduced air flow

— Install the equipment in a rack so that the amount of air

flow required for safe operation of the equipment is not compromised.

3.

Mechanical loading

— Mount the equipment in the rack so that a hazardous

condition is not achieved due to uneven mechanical loading.

4.

Circuit overloading

— Connect the equipment to the supply circuit and

consider the effect that circuit overloading might have on overcurrent

protection and supply wiring. Appropriate consideration of equipment

nameplate ratings should be used when addressing this concern.

5.

Reliable earthing (grounding)

— Maintain reliable grounding of rack-

mounted equipment. Pay particular attention to supply connections other

than direct connections to the branch circuit (e.g. use of power strips).

Rack mounting with a rack shelf

Mount the unit on an optional 1U rack shelf and install blank panels or other units

to the rack shelf as shown below.

Use 2 mounting holes on
opposite corners.

(2) 4-40 x 3/16"
Screws

1U Universal Rack Shelf

Both front false faceplates
use 2 screws.

QuarterRackStandardShelf

1/4 Rack Width Front False
Faceplate

1/2 Rack Width Front False
Faceplate

QuarterRackVersaToolsShelf

(2) 4-40 x 3/16"
Screws

Use 2 mounting holes on
opposite corners.

VersaTools Rack Shelf

1/4 Rack Width Front
False Faceplate