Extron Electronics IPL 250 Reference Manual User Manual

Page 31

Advertising
background image

3-5

IPL 250 • Software-based Configuration and Control

You can reconnect using either Telnet or a Web browser to verify that the

update was successful.

6.

After verifying that the IP address change was successful, enter and issue the

arp –d command at the DOS prompt. For example:

arp –d 10.13.197.7 removes 10.13.197.7 from the ARP table

or

arp –d* removes all static IP addresses from the ARP table.

Configuring the IPL for network use via a Web browser

The default Web pages that are preloaded on the IPL 250 are compatible with

popular Web browsers such as Microsoft Internet Explorer (version 5.5 or higher)

or Mozilla Firefox (version 1.0 or higher). However, the IPL and the PC must both

be part of the same subnet before they can communicate via the LAN port. You

must change the PC’s IP address to one that is on the same subnet as the default IP

address of the IPL 250 (192.168.254.254).

N

This method requires a crossover cable.

See page 2-7

for cabling details.

N

Make a note of the host PC's TCP/IP configuration before changing its IP

address and make sure the PC and IPL 250 are on the same subnet.

1.

Temporarily change the host PC’s IP address.

See “Setting up the PC for

IP communication with an IPL 250”

later in this chapter for step-by-step

instructions.

2.

Obtain a valid IP address for the controller from your network administrator.

3.

Launch the Web browser on the connected PC (for which you set up the

network configuration earlier), and enter

http://192.168.254.254/ in

the address box. The IPL 250’s default Web page is displayed.

Advertising