Extron Electronics IPL 250 Reference Manual User Manual

Page 23

Advertising
background image

2-9

IPL 250 • Hardware Features and Installation

(+)

(+)

(+)

(+)

(+)

(-)

(-)

(-)

(-)

(-)

(+)

(+)

(-)

(-)

(+)

(-)

(+)

(-)

IR Signal

IR Signal

IR Signal

IR Signal

Ground

Single and Dual IR Emitter

Two Single IR Emitters

Dual IR Emitters

Two Single and 0ne Dual IR Emitter

Ground

Ground

Ground

(+)

(+)

(-)

(-)

(+)

(-)

(+)

(–)

Black wire
w/white stripe

Black wire

Legend

Wiring emitters for IR control

f

Relay ports — Four relay ports provide control for power, screen/projector

lifts, window coverings, and similar items, when trigger events occur.

These relay contacts may be used to control any

equipment as long as the contact specifications

of a total of 24 volts at 1 ampere are not exceeded

for each port. These relays are normally open by

default.

When activated, the closed contacts open, and

the open contacts close. They can be set up to

operate in one of two ways:

latching (brief contact) (press to turn on, press

to turn off), or

momentary (timed) (press to turn on, timeout

to turn off).

In the timed mode the default timeout period is

½ second (500 ms). Use the GC software or SIS

commands to change the length of the timeout

period. See

X6#

in “Serial Communication”

,

chapter 4, for details.

g

Input (contact closure input) ports

To allow the IPL 250 to monitor devices to

trigger events, connect a switch, sensor, or

similar item to one of these four ports. See the

figure at right for an example.

A 1k ohm pull-up resistor in a TTL (5 VDC)

circuit senses external switch or contact

closure. After these ports have been

configured, when the circuit between a signal

pin and a ground pin is closed, each port can

trigger events (such as toggling relays, issuing

commands, or sending an e-mail).

h

MAC address — This is the unique user

hardware ID number (MAC address) of the

unit (for example, 00-05-A6-00-00-01). You

may need this address during configuration.

RELAY

1

2

Closed

Normally

open

IPL 250
Rear Panel

To Room

Control

Equipment

INPUT

1 2 3 4

IPL 250
Rear Panel

Switch,
Sensor

2

1

3

4

Heat Shrink
Over Shield