Special applications, cont’d – Extron Electronics IPL 250 Reference Manual User Manual

Page 84

Advertising
background image

Special Applications, cont’d

IPL 250 • Special Applications

5-4

Example: SSI use in notification e-mails

One simple way to use host SSI commands is to customize e-mail messages that the

IPL 250 sends in response to a monitored condition or event. In the example shown

below, the disconnection e-mail uses SSIs to insert the unit name, IP address, and

time into an e-mail that is sent when the IPL 250 detects that a device attached to it

has been disconnected or when a switch connected to a contact input port closes or

opens. For more information on commands, see the

Command/response table for

SIS commands

in chapter 4.

How these commands are typed into the Global Configurator Email Manager:

WCN

|

is the

SIS command
to read the IPL’s
unit name.

WCI

|

is the SIS

command to
read the IPL’s IP
address.

WCT

|

is the

SIS command
to read the date
and time.

2

1

3

Resulting e-mail that is sent out upon equipment disconnection:

<!--#echo var="W CN

|"-->

results: unit name.

<!--#echo var="W CI

|"-->

results: unit’s IP address.

<!--#echo var="W CT

|"-->

results: date and time.

2

1

3

SSI use in an IPL’s Web page

Reference notes:
An __.shtml file can be uploaded to the IPL 250 by using one of the following:
• the File Management tab of the factory embedded Web page

(http://<unit’s IP address>/nortxe_index.html)

• an SIS command (see “File streaming commands” in the SIS tables in chapter 4)

Advertising