Hardware Features and Installation, cont’d

IPL 250 • Hardware Features and Installation

2-8

For bidirectional RS-232 communication, the transmit, ground, and receive

pins must be wired at both the IPL 250 and the other device. Each projector

or other device may require different wiring. For details, refer to that

equipment’s manual or to the Extron device driver communication sheet.

N

Maximum distances between the IPL and the device being controlled may vary

up to 200 feet (61 m). Factors such as cable gauge, baud rates, environment,
and output levels (from the IPL and the device being controlled) all affect
transmission distance. Distances of about 50 feet (15 m) are typically not a
problem. In some cases the IPL may be capable of transmitting and controlling a
given device via RS-232 up to 250 feet (76 m)
away, but the RS-232 response levels of that device
may be too low for the IPL to detect.

Extron Comm-Link (CTL and CTLP) cable is

recommended for these connections. Before

inserting wires in the connectors, strip the cable and

apply heat shrink as shown at right.

T

For best results and to avoid short circuits, Extron
recommends using shielded wires or wires insulated
using heat shrink (instead of bare wires) for the
common/drain wires.

Unidirectional control and communication connections

e

IR output ports — An IPL 250 can use infrared signals to control up to 16

devices. You can connect one of these ports directly to the wired IR port of

another device. Or you can insert the wires from up to four IR Emitters in

an IR port and place the emitters’ heads over or next to the devices’ IR signal

pickup windows. The figure below shows some wiring examples.

IR

1

S G S G

2

(+)

(-)

(+)

(+)

(-)

(-)

IPL 250
Rear Panel

Two Single IR Emitters

To Projector,

Panel Display,

or Source

Device’s Wired

IR Remote Port

Ground ( )

IR Output Signal

Unidirectional IR

IR Output

Ground ( )

Strip wires

3/16”

(5 mm)

max.

Wiring the IR ports

N

Each emitter must be within 100’ of the IPL for best control results.

If using all single emitters or all double emitters, wire the emitters in

parallel.

If using a mix of both single and dual emitters, see the following figure

and the IR Emitter Installation Guide, part number 68-808-01.

3/16”

(5 mm) Max.

7/8”

(22 mm)

Heat Shrink on

Outer Jacket to

Inner Conductor

Transition

Extron

Comm-Link Cable