Input sub-menu, Input sub‑menu, Stream – Extron Electronics VN-Matrix 250 User Guide User Manual
Page 102: System control

Stream
The
LAN2-Stream
editing screen allows you to adjust the following properties of the
streaming network:
z
IP address — follow steps 1‑4 of the Control section on the previous page.
z
Subnet mask — follow steps 1‑4 of the Control section.
z
Gateway — follow steps 1‑4 of the Control section.
z
MTU — use either rotary encoder to adjust the MTU value (150 ‑ 9000).
ATTENTION:
•
The MTU setting adjusts the data payload in each network packet. The
default setting of 1500 does not normally require adjustment.
•
All devices in the network should be set to the same value. Setting different
values for different devices may cause failures in the VN‑Matrix streaming
network.
z
Mode — use either rotary encoder to toggle between 100 and 1000 Mbps network
modes.
z
DHCP — use either rotary encoder to toggle between enable and disable.
System Control
The
System Control editing screen allows you to configure the IP address and port
number of the system controller.
Input Sub-menu
The
Input sub‑menu allows you to select the input source, enable or disable the loop‑
through video signal, and enable or disable the power save feature for the loop‑through
signal.
Input
MENU
NEXT
Select auto
NEXT
Select:
auto
HDMI
VGA
input
Select:
Enabled
Disabled
NEXT
Loop through
[Enabled]
Select:
Enabled
Disabled
NEXT
Power save
[Enabled]
NEXT
Figure 79.
VNE 250 Encoder Input Sub-menu
VNM 250 • Front Panel Menu Configuration
96