Extron Electronics VN-Matrix 250 User Guide User Manual
Page 111

Stream
The
LAN2-Stream editing screen allows you to adjust the following properties of the
streaming network:
z
IP address — follow steps 1‑4 of the Control section on the previous page.
z
Subnet mask — follow steps 1‑4 of the Control section.
z
Gateway — follow steps 1‑4 of the Control section.
z
MTU — use either rotary encoder to adjust the MTU value (150 ‑ 9000).
ATTENTION:
•
The MTU setting adjusts the data payload in each network packet. The
default setting of 1500 should not normally require adjustment.
•
All devices in the network should be set to the same value. Setting different
values for different devices may cause failures in the VN‑Matrix streaming
network.
z
Mode — use either rotary encoder to toggle between 100 and 1000 Mbps network
modes.
z
DHCP — use either rotary encoder to toggle between enable and disable.
System control
The
System Control
editing screen allows you to configure the
IP address and port
number of the system controller.
VNM 250 • Front Panel Menu Configuration