RS-232 Pass-through Configuration
The Coms port on the rear panel of the encoder (see
,
R
on page 13), or decoder
,
R
on page 13) is used for RS‑232 pass‑through communications, allowing
a control device connected to one VNM 250 unit (the server) to control remote devices
connected to other VNM 250 units (clients).
Serial data received by one VNM 250 unit is transmitted over the network, using
TCP/IP, and then converted back to serial data at the target VNM 250 unit. Data flow is fully
bi‑directional.
Units that are configured for this type of data flow are called pass‑through groups (see
on page 18).
Pass-through Coms Server Configuration
1.
On the
Device List
page, click on the device you want to configure as the server.
2.
Click the
Peripherals
tab. The page opens with the
Serial
Port
Control
panel on
the left hand side of the window:
1
1
2
2
Figure 72.
Serial Port Control Panel
3.
From the
mode
drop‑down list, select
server
(see figure 72,
1
).
4.
Change other settings, as required.
5.
Click
update
(see figure 72,
2
), followed by
Save All
at the top of the page.
Pass-through Coms Client Configuration
1.
On the
Device List
tab, select the device you want to configure as a client.
2.
Click the
Peripherals
tab (see figure 69).
3.
From the
mode
drop‑down list, select
client
(see figure 73,
1
). This reveals the
destination box (see figure 73,
3
).
1
1
2
2
3
3
Figure 73.
Serial Port Control Panel with Destination menu
4.
From the destination drop‑down list, select
passthrough
for the appropriate server (see
figure 73,
3
).
5.
Change the other settings as required, then click
update
(see figure 73,
2
).
6.
Click
Save All
at the top of the page.
7.
Repeat steps 1‑6 for other client devices.