RS-232 Pass-through Configuration

The Coms port on the rear panel of the encoder (see

figure 6

,

R

on page 13), or decoder

(see

figure 7

R

on page 13) is used for RS‑232 pass‑through communications, allowing

a control device connected to one VNM 250 unit (the server) to control remote devices
connected to other VNM 250 units (clients).
Serial data received by one VNM 250 unit is transmitted over the network, using
TCP/IP, and then converted back to serial data at the target VNM 250 unit. Data flow is fully
bi‑directional.
Units that are configured for this type of data flow are called pass‑through groups (see

RS-232 Pass-through

on page 18).

Pass-through Coms Server Configuration

1.

On the

Device List

page, click on the device you want to configure as the server.

2.

Click the

Peripherals

tab. The page opens with the

Serial

Port

Control

panel on

the left hand side of the window:

1

1

2

2

Figure 72.

Serial Port Control Panel

3.

From the

mode

drop‑down list, select

server

(see figure 72,

1

).

4.

Change other settings, as required.

5.

Click

update

(see figure 72,

2

), followed by

Save All

at the top of the page.

Pass-through Coms Client Configuration

1.

On the

Device List

tab, select the device you want to configure as a client.

2.

Click the

Peripherals

tab (see figure 69).

3.

From the

mode

drop‑down list, select

client

(see figure 73,

1

). This reveals the

destination box (see figure 73,

3

).

1

1

2

2

3

3

Figure 73.

Serial Port Control Panel with Destination menu

4.

From the destination drop‑down list, select

passthrough

for the appropriate server (see

figure 73,

3

).

5.

Change the other settings as required, then click

update

(see figure 73,

2

).

6.

Click

Save All

at the top of the page.

7.

Repeat steps 1‑6 for other client devices.

VNM 250 • Configuration with the VNM 250 GUI