Technical data

610.44440.40.000

10 / 32

© Gardner Denver Deutschland GmbH

3.2 Electrical

data

See motor rating plate.

3.3

Operating conditions normal operation

Temperatures

Temperatures of the gases / vapours

[°C]

[°F]

max. +80

max. +176

For higher media temperatures provisions have to
be made in the system to protect against burning,
e.g. fitting of guards.
In this case one of the following provisions can be
made:
 increase of the operating-liquid flow-rate to 2.5

times (2BV2 …) or to 2 times (2BV5 …) the de-
sign operating-liquid flow-rate (cooling circula-
tion)

 installation of a pre-condenser

Temperature of the operating-liquid

[°C]

[°F]

max. +80

max. +176

min. +5

min. +41

Nominal value:

+15 +59

Ambient temperature

[°C]

[°F]

max. +40

+104

min. +5

+41

Pressures

Min. suction pressure p

1 min

for operation

with cavitation-protection
Cavitation-protection tapping open (2BV2 0.. and
2BV5 1.. only)

[mbar abs.]

[psia]

max. achievable under-pressure (full throttling)
As a general rule:
The higher the temperature, the lower the suction
capacity, i.e. the higher the minimum achievable
suction pressure.

610.44440.99.B04

-

fl

[°C, °F] = temperature of the operating-

liquid

-

p

1

[mbar abs., psia] = absolute suction pres-

sure

Fig. 2: Pressure characteristics at varying

operating conditions

50

100

200

250

300

p

1

[m

b

ar ab

s.

]

0

20

40

60

fl

[°C]

80

150

0,5

1

1,5

2

2,5

3

3,5

4

4,5

0

fl

[°F]

p

1

[

p

sia]

50

100 150 200

Advertising
This manual is related to the following products: