K d k – Elmo Rietschle L-BV5 Operating instructions User Manual

Page 12

Advertising
background image

Technical data

610.44440.40.000

12 / 32

© Gardner Denver Deutschland GmbH

Design operating-liquid flow [ft³/h]
Type

Flow rate

Vacuum operation

in the pressure range [psi]

0.479-

2.90

2.90-

7.25

>7.25

Flow

rate,

com-

pressor

opera-

tion

2BV2 060

7.06 7.06 7.06 7.06

2BV2 061

8.12 8.12 8.12 8.83

2BV2 070

9.89 /
12.0*

4.94 /
6.0*

4.94 /
6.0*

17.66

2BV2 071

15.89

8.12
9.89*

8.12
9.89*

24.72

2BV5 110

28.25 12.36 10.59 31.78

2BV5 111

42.38 14.13 12.36 42.38

2BV5 121

42.38 /
52.97*

14.13 12.36 52.97

2BV5 131

63.57 15.89 14.13 63.57

2BV5 161

84.76 24.72 17.66 84.76

2BV5 410

28.25 28.25 19.42 28.25

* Value for 50 Hz operation / value for 60 Hz op-

eration
All other values for 50 Hz and 60 Hz operation.

Quantity of operating-liquid for first fill
Type

[l]

[gal (US)] [gal (UK)]

2BV2 060

0.5 0.132

0.110

2BV2 061

0.5 0.132

0.110

2BV2 070

1.0 0.264

0.220

2BV2 071

1.0 0.264

0.220

2BV5 110

3.0 0.793

0.660

2BV5 111

3.0 0.793

0.660

2BV5 121

3.0 0.793

0.660

2BV5 131

3.0 0.793

0.660

2BV5 161

8.0 2.113

1.760

2BV5 410

3.0 0.793

0.660

Maximum permissible quantity of water carried
along through the inlet connection

1x

1x

+ D

1x

+ K

D

K

610.44440.99.B05

Type

Continuous op-

eration [D]*

max. 2 sec

[K]*

2BV2 …

2.5x 7x

2BV5 1..

2.5x 5x

2BV5 4..

7x 7x

* 1x = design operating-liquid flow


































Advertising