Fault

Cause

Correction

Remedy

Excessive backpres-
sure in the discharge
connection

 Reduce the backpressure.

Operator

Proportion of liquid
entrained in the main
flow is too high

 Reduce the proportion of liquid.

Operator

Impeller does not ro-
tate freely

See "Impeller does not rotate freely", page 27

See "Decalcifying the unit", page 26.

Operator

Power con-
sumption
too high

Build up of lime-scale
or
contamination

See "Flushing the pump casing", page 26.

Operator

No operating-liquid
supply

When operating with supply of the operating-liquid:
 Check and correct the operating-liquid flow-rate. (see

chapter 7.4, "Checking and correcting the operating-
liquid flow-rate, page 22).

When operating with self-suction of the operating-liquid:
 See 7.3, "Operation with self-suction of the operating-

liquid", page 22.

 Clean out the operating-liquid supply hose.
 Increase the diameter of the operating-liquid supply

hose.

Operator

Large-scale leak in the
system.

 Seal off leaks in the system.

Operator

Unit does
not generate
a vacuum

Incorrect direction of
rotation

 Change the direction of rotation by switching polarity

between two of the electrical power supply phases.

Electrician

Insufficient operating-
liquid

See "No operating-liquid supply", page 28.

Operator

Operating-liquid too
warm

 cool the operating-liquid or increase the flow-rate (see

chapter 7.4, "Checking and correcting the operating-
liquid flow-rate", page 22).
(nominal temperature: 15°C [59 °F]).

Operator

Erosion / Corrosion

 Inspection of the casing, the impeller and the control

disk.

 Renew the affected components.

Service

Leakage in the system  Repair leakage in the system.

Operator

Rotary seal leaking

 Replace

rotary

seal.

Service

Motor connection in-
correct

 Check and repair motor connection.

Electrician

Electrical power sup-
ply incorrect

 Check and repair electrical power supply.

Electrician

System
generates
too little
vacuum

Unit is too small

 Install a larger unit.

Operator

Cavitation in the unit 2BV2 … and 2BV5 1..

 Connect

separator

cavitation-protection
hose (ancillary) or
clean out cavitation-
protection system.

2BV5 4..
 Check that the pressure set-

ting is in accordance with the
permitted operating pressure.

Operator

Squealing
noises

Operating-liquid flow-
rate too high

 Check the operating-liquid flow-rate and if necessary

reduce it (see chapter 7.4, "Checking and correcting
the operating-liquid flow-rate", page 22).

Operator

Leakage in
the unit

Defective seals

 Check

the

seals.

Service