8 Decommissioning the machine

and shutting it down for a longer
period of time

WARNING

Improper handling of the equipment can re-
sult in serious or even fatal injuries!
Have you read the safety notes chapter 1,
"Safety", page 4 above?
If not then you are not allowed to carry out any
work on or with the equipment!


8.1 Draining

down

DANGER

Electrical hazard!
Before starting work on the unit or system, the
following precautions are to be taken:
 de-energize it.
 protect it from being switched on again.
 make sure that it is de-energized.
 earth it and bypass it.
 cover or block off adjoining parts which are

still live.

WARNING

Hazard in case of overpressure and negative
pressure!
Hazard presented by leaking media!
Before starting work on the unit or system:
 shut off the operating-liquid supply.
 vent the piping and the unit (de-pressurize).

WARNING

Danger of burns or scalding from hot sur-
faces on the unit and from hot media!
 Do not touch when in operation!
 After shutdown, allow system to cool down!

WARNING

Hazard presented by combustible, caustic or
poisonous substances!
In order to protect persons and the environment:
Units that have come into contact with hazard-
ous substances must be flushed out whilst run-
ning, before opening the unit up.




 Switch off the power supply.

 Take the abovementioned precautionary

measures for safety when working on the unit
or system.

 Place suitable drain-off containers underneath

the cover.

 Open the screwed plugs in all drain tappings

(item 4, page 3).

 Allow the liquid to drain off.

 Whilst doing so turn the shaft in its normal

direction from time to time (Fig. 15, page 23).
For 2BV2 …:

-

screw in an M8 bolt of sufficient length into
the shaft end on the external fan side.

-

use a wrench to turn the shaft manually.

For 2BV5 …:

-

remove the fan guard.

-

turn the external fan by hand.

 if necessary remove the fixings from the

mounting feet and tip the unit over by 45° to-
ward the cover side.

 continue these measures until no further liquid

comes out.

 close the screwed plugs in all drain tappings

(item 4, page 3).
Tightening torques: 2 3 Nm
[1.48 ... 2.21 ft lbs].

for 2BV2 … remove the bolt from the shaft

end on the fan side.

For 2BV5 … refit the fan guard.

 reinstall the fixings in the mounting feet.

2BV2 ...

2BV5 ...

610.44440.99.B16

Fig. 15: Turning the shaft