Elmo Rietschle L-BV5 Operating instructions User Manual

Page 7

Advertising
background image

Correct use of the equipment

© Gardner Denver Deutschland GmbH

7 / 32

610.44440.40.000

The units

 create a vacuum or overpressure.

 are used to extract, deliver and compress the

following gases / vapours:

-

all dry and humid gases,
which are not explosive, flammable, ag-
gressive
or poisonous,

-

Air or air-vapour mixtures.

-

In the case of explosive, flammable, ag-
gressive or poisonous gases / vapours,
please consult the manufacturer.

-

The gases / vapours must be free of solid
matter.
Small quantities of light suspended matter
or liquids can be conveyed along too.

 are designed for operation with the following

operating-liquids:

-

Water
of pH-value between 6 and 9,
that are free of solid matter (e.g. sand).

-

in the case of pH-values or operating-liquids
deviating from the above, please contact
the manufacturer.

 are suitable for a deep vacuum range.

 are fitted with one of the following types of

drive motor:

-

standard design,

-

explosion-protected design.

These operating instructions are only applica-
ble for units in the standard design.
For the explosion-protected design
(RL 94/9/EG) - see supplementary special
operating instructions.

 are available in two constructions:

-

cast iron construction for normal require-
ments,

-

stainless steel construction for higher corro-
sion-resistance and hygiene requirements
(only 2BV2 070, 2BV2 071, 2BV5 1..).

 are designed for industrial plants.

 Are designed for continuous operation.
For operation of the units, please refer to chap-
ter 3, "Technical data", page 8 hereunder for the
specified tolerance limits which must be adhered
to.









Foreseeable misuse

The following are forbidden:

 to use the unit in non-industrial systems,

to operate the system if it does not include the
necessary precautions and protective devices,
e.g. protection against touching by small fin-
gers,

 to operate the unit in spaces in which explo-

sive gases may be present, insofar as the unit
is not specifically designed for such condi-
tions;

 extraction, conveyance and compression

of explosives, combustible, aggressive or poi-
sonous media,
insofar as the unit is not specifically designed
for such conditions,

 operation of the unit at any values other than

those specified in chapter 3, "Technical data",
page 8 hereunder.

Modifications to the units are forbidden for safety
reasons.
The operator is allowed to carry out maintenance
and repair work only to the extent described in
these operating instructions.
Maintenance and repair work which goes beyond
this may only be carried out by companies which
have been authorised by the manufacturer (ask
the service department for details).






























Advertising