Operation

610.44440.40.000

22 / 32

© Gardner Denver Deutschland GmbH

7.3

Operation with self-suction of the oper-
ating-liquid

 When switching the unit on there should be a

vacuum in the suction line (item 8, Fig. 10,
page 17) of min. 900 mbar abs. [13.1 psia].

 When switching on the liquid level in the sup-

ply line (item 7, Fig. 10, page 17) or in the
storage vessel (item 9, Fig. 10, page 17) must
be at the same level as the operating-liquid
connection on the unit (item a, Fig. 10,
page 17).

 During operation the liquid level in the storage

vessel (item 9, Fig. 10, page 17) may not sink
below approx. 1 m [3.28 ft] under the level of
the operating-liquid connection (item b, Fig.
10, page 17).

Starting the unit up

 Switch on the power supply.

 The unit begins to draw in the operating-liquid

and the gases / vapours to be handled.

Switching the unit off:

 Switch off the power supply.

 The unit ceases drawing in the operating-

liquid and the gases / vapours.






























7.4

Checking and correcting the operating-
liquid flow-rate

 using the flow meter (item 2Fig. 8, page 17, or

item 2, Fig. 9, page 17)

OR

 by measuring the quantity of operating-liquid

per unit of time flowing from the discharge
connection using a measuring cup (Fig. 14,
page 22)

B

C

610.44440.99.B15

B Operating-liquid supply line
C Discharge line

Fig. 14: Adjusting the operating-liquid flow-rate:

Measuring the flow-rate using a measuring
cup

Correcting the operating-liquid flow-rate for
unit with operating-liquid supplied

 Correct the operating-liquid flow-rate by

means of the throttle valve (item 3, Fig. 8,
page 17, or item 3, Fig. 9, page 17).
see the table, "Design operating-liquid flow",
page 11.

For self-suction of operating-liquid the oper-
ating-liquid flow-rate varies as follows:

The higher the suction pressure, the lower the
operating-liquid flow-rate.
The lower the suction pressure, the lower the
operating-liquid flow-rate.