Decommissioning the machine and shutting it down for a longer period of time

610.44440.40.000

24 / 32

© Gardner Denver Deutschland GmbH

8.2

Preparations for long-term shutdown

For longer shutdown periods (from approx.
4 weeks) or in the event of frost hazard proceed
as follows:

Cast iron construction:

 Drain down the unit as described in chap-

ter 8.1, "Draining down", page 23.

 Remove the piping / hoses from the suction

and discharge connections.

 Pour a preserving agent (anti-rust oil, e.g.

Mobilarma 247 supplied by the Mobil Oil Co.)
into the open suction and discharge connec-
tions.
Charge required:
for 2BV2 …:
½ l [0.132 gal (US); 0.110 gal (UK)]
For 2BV5 …:
1 l [0.264 gal (US); 0.220 gal (UK)]

 Seal off the suction and discharge connec-

tions as well as the operating-liquid connec-
tion or alternatively reinstall the piping / hoses.

 Start and stop the unit briefly to distribute the

preserving agent.

There are two alternatives for storage:

-

the unit remains connected up to the sys-
tem,

-

or the unit is removed and stored sepa-
rately.

Stainless steel and bronze constructions:

 Drain down the unit as described in chap-

ter 8.1, "Draining down", page 23.

There are two alternatives for storage:

-

the unit remains connected up to the sys-
tem,
OR

-

or the unit is removed and stored sepa-
rately.

















8.3 Storage

conditions

This chapter applies to:

 new

units,

 units that have been prepared for long-term

shutdown as described in chapter 8.2,
"Preparations for long-term shutdown",
page 24.

In order to avoid damage during shutdown and
storage periods, the ambient conditions should
be as follows:

 dry,

 free of dust,

 low vibration (effective value for the speed of

oscillation veff ≤ 2.8 mm/s [0.11"/sec]).

 ambient

temperature:

max. +40 °C [+104 °F].

CAUTION

Risk of material damage due to high tem-
peratures!
Storage at ambient temperatures in excess of
40 °C [104 °F] can result in damage to the wind-
ings and reduced re-greasing intervals.


8.4

Commissioning after a long shutdown
period

CAUTION

Risk of material damage due to insufficient
lubrication of roller bearings after long term
storage!
 If the unit is stored for a period of more than

2 years then the roller bearings will require
new greasing (see Re-grease or renew roller
bearings, page 27).

 Drain off the preserving agent (chapter 8.1,

"Draining down", page 23).
No further cleaning of the unit is necessary.

 Dispose of the preserving agent in accor-

dance with the manufacturer's recommenda-
tions.

 In the event that the impeller does not rotate

freely:
Decalcifying the unitt or To free it, rotate the
shaft (chapter 9.1, "Maintenance", page 26).

 For new units proceed as described in chap-

ter 5, "Installation", page 14.

 For units having been shut down for long pe-

riods proceed as described in chapter 6
"Commissioning", page 14.