Elmo Rietschle L-BV7 User Manual

Page 16

Advertising
background image


610.48060.40.000

16 / 64

© Gardner Denver Deutschland GmbH

Technical Data


Weight

Type Weight
[kg]

[lbs]

2BV7 060-1A.0.

approx. 16

approx. 35.3

2BV7 060-2A.0.

approx. 17

approx. 37.5

2BV7 060-3A.0.

approx. 18

approx. 39.7

2BV7 061-1A.0.

approx. 22

approx. 48.5

2BV7 070-1A.0.

approx. 31

approx. 68.3

2BV7 070-2A.0.

approx. 35

approx. 77.2

2BV7 070-3A.0.

approx. 48

approx. 106

2BV7 071-1A.0.

approx. 39

approx. 86

2BV7 071-2A.0.

approx. 50

approx. 110

2BV7 071-3A.0.

approx. 56

approx. 123


Minimum distances for heat dissipation

Minimum distance from

fan guard to adjacent surface

Type

[mm] [inches]

2BV7 060

34

1.34

2BV7 061

34

1.34

2BV7 070

53

2.09

2BV7 071

53

2.09


Noise level

Measuring-surface sound pressure level as per
EN ISO 3744, measured at distance of 1 m
[3.28 ft] with medium throttling (100 mbar abs.
[1.45 psia]) and connected lines, tolerance 3
dB (A).

1-m measuring-surface sound

pressure level L [dB (A)]

Type

at 50 Hz:

at 60 Hz:

2BV7 060

70

2BV7 061

70

2BV7 070

72

2BV7 071

70

76


Limit speeds for supply by converter

Type n

[rpm]

2BV706 4,800
2BV707 4,000



4.2 Electrical

data

See drive motor rating plate.


4.3 Operating

conditions

Temperatures

max. +80 °C [max. +176 °F]

Temperature
of pumped
gases/vapors:

At higher fluid temperatures,
measures must be taken on
the system to prevent burns,
e.g. mount separating safety
device (cover).
max. +80 °C [max. +176 °F]
min. +5 °C

[min. +41 °F]

Operating-
liquid
temperature:

Nominal
value:
+15 °C



[+59 °F]

max. +40 °C [+104 °F]

Ambient
temperature:

min. +5 °C

[+41 °F]



Pressures

Min. inlet
pressure:

Dependent on the operating
liquid temperature
(see Fig. 2, Pg. 17)

When this temperature is
dropped below, the hose of
the liquid separator
(accessory) must be
connected to the connection
for cavitation protection
(Fig. 7, Pg. 25, Item 4).

Max.
discharge
pressure
during
vacuum-pump
operation:

1.1 bar abs. [16.0 psia]

8 bar abs.

[116 psia]

Max.
permissible
pressure in
pump-motor
unit:

If higher pressures can occur
in the system, then
corresponding protective
devices must be provided.


Max. discharge pressure p

2 max

during

compressor operation (at inlet pressure p

1

=

1 bar abs. [14.5 psia]):

p

2 max

[bar abs.]

[psia]

Type

at
50 Hz:

at
60 Hz:

at
50 Hz:

at
60 Hz:

2BV7

060 2 2 29.0

29.0

2BV7

061 2 2 29.0

29.0

2BV7 070

3

2.5

43.5

36.3

2BV7

071 3.5 2.5 50.8 36.3

Advertising