Commissioning

8.3

Operation with operating-liquid feed

See Fig. 9, Pg. 31; and Fig. 10, Pg. 31, as well as Fig. 11, Pg. 32 and Fig. 12, Pg. 32.

Proceed as follows here:

Method A:

1) Set pre-pressure of operating liquid (Fig. 9,
Pg. 31):

 Set a pre-pressure p

A

in the feed pipe for

the operating liquid (Item A) around
approx. 1 bar [14.5 psi] above the inlet
pressure p

B

in the inlet pipe (Item B).


2) Start up the unit:

For non-automatic operation (Fig. 11, Pg. 32):

 Open the stop valve (Item 4) manually.

The operating liquid is fed in.

 Switch on the unit.

For automatic operation (Fig. 12, Pg. 32):

 Switch on the unit.

 The solenoid valve (Item 4) opens

and the operating liquid is fed in.


Method B:

1) Start up the unit:

For non-automatic operation (Fig. 11, Pg. 32):

 Open the stop valve (Item 4) manually.

The operating liquid is fed in.

 Switch on the unit.

For automatic operation (Fig. 12, Pg. 32):

 Switch on the unit.

 The solenoid valve (Item 4) opens

and the operating liquid is fed in.


2) Check the operating-liquid flow rate:

 with the flow meter (Fig. 11, Pg. 32, and

Fig. 12, Pg. 32, Item 2)

OR

 by measuring the volume of operating liquid

per unit of time that exits at the discharge
connection with a graduated vessel
(Fig. 10, Pg. 31)


3) Set/correct the operating-liquid flow rate:

 via the control valve (Fig. 11, Pg. 32, and

Fig. 12, Pg. 32, Item 3)

 Nominal operating-liquid flow rate:

For nominal values, see Chapter 4.3,
"Operating conditions", Section "Nominal
operating-liquid flow rate", Pg. 17.

A

B

p = p + 1 bar

A

B

p = p + 14.5 psi

A

B

A

B


Fig. 9: Setting the operating-liquid flow rate:
Setting pre-pressure


Fig. 10: Setting the operating-liquid flow rate:
Measuring the volume with a graduated vessel


A Feed pipe for operating liquid
B Inlet

pipe


A Feed pipe for operating liquid
B Drain pipe for operating liquid