Operation

9 Operation

WARNING

Danger due to gauge pressure
and vacuum!

Danger due to escaping fluid!

Danger due to rotating parts!

The pump-motor unit may only
be put into operation when the
following conditions are met:
 Fan guard and vacuum

pump/compressor housing
are mounted.

 The lines to the discharge

connection, inlet connection
and operating-liquid port are
attached.

 The lines and connections

have been tested for strength
and leaks.

CAUTION

If the unit is run dry, the
mechanical seal will be
destroyed in a matter of seconds!

DO NOT switch on as long as the
unit is not filled with operating
liquid!

WARNING

Danger of burns and scalding
from hot surfaces of the pump-
motor unit and from hot fluids!

Do not touch during operation!
Allow to cool after shut-down!

NOTICE

Maximum permissible quantity of
water entrained via the inlet
connection:
See Fig. 13, Pg. 32.


9.1 Self-priming

operation

Follow the instructions contained in
Chapter 8.2, "Self-priming operation", Pg. 30
for this operating mode.


9.2

Operation with operating-liquid feed


Start-up

For non-automatic operation (Fig. 11, Pg. 32):

 Open the stop valve (Item 4) manually.

The operating liquid is fed in.

 Switch on the unit.

For automatic operation (Fig. 12, Pg. 32):

 Switch on the unit.

 The solenoid valve (Item 4) opens

and the operating liquid is fed in.



Shut down:

For non-automatic operation (Fig. 11, Pg. 32):

 Switch off the pump-motor unit.

 Close the stop valve (Item 4) manually.

Feeding of the operating liquid is cut off.

 The following applies for the control valve

(Item 3) for setting the operating-liquid flow
rate:
In case of an interruption in operation, the
valve setting (i.e. the valve position or the
open valve cross-section) is not changed.


For automatic operation (Fig. 12, Pg. 32):

 Switch off the pump-motor unit.

 The solenoid valve (Item 4) closes,

and feeding of the operating liquid is cut off.

 The following applies for the control valve

(Item 3) for setting the operating-liquid flow
rate:
In case of an interruption in operation, the
valve setting (i.e. the valve position or the
open valve cross-section) is not changed.