Technical data, Operating-liquid filling amount for priming – Elmo Rietschle L-BV7 User Manual

Page 17

Advertising
background image


© Gardner Denver Deutschland GmbH

17 / 64

610.48060.40.000

Technical Data


0

50

100

150

200

250

300

0

20

40

60

80

fl

[°C]

p

1

[mb

a

r

a

b

s

.]

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

0

50

100

150

200

f l

[°F]

p

1

[p

si

a]

Fig. 2: Minimum inlet pressure/cavitation limit

fl

[°C, °F]

= Temperature of operating liquid

p

1

[mbar abs., psia]

= Inlet pressure abs.


The minimum permissible inlet pressure of the pump-motor unit is dependent on the temperature of the operating
liquid.
During operation without cavitation protection, the minimum inlet pressure must be set above the shaded area.

Nominal operating-liquid flow rate

(with dry air extraction and with water at 15°C
[59 °F] as operating liquid)

Flow rate

[m³/h] [ft³/h]

Type

at
50 Hz:

at
60 Hz:

at
50 Hz:

at
60 Hz:

2BV7

060

0.20 0.20 7.06 7.06

2BV7

061

0.23 0.23 8.12 8.12

2BV7

070

0.28 0.34 9.89 12.0

2BV7

071

0.45 0.55 15.9 19.4



Operating-liquid filling amount for priming

Filling amount

Type

[l]

[gal (US)] [gal (UK)]

2BV7 060

0.40

0.106

0.088

2BV7 061

0.55

0.145

0.121

2BV7 070

0.80

0.211

0.176

2BV7 071

1.10

0.291

0.242