7.2

Electrical connection (motor)

The electrical connection must be carried out
as follows:

 according to the applicable national and

local laws and regulations,

 according to the applicable system-

dependent prescriptions and requirements,

 according to the applicable regulations of

the utility company.

DANGER

Electrical danger!

Malpractice can result in severe
injuries and material damage!

DANGER

Electrical danger!

The electrical connection may be
carried out by trained and
authorized electricians only!

DANGER

Electrical danger!

Before beginning work on the
unit or system, the following
measures must be carried out:
 Deenergize.

 Secure against being

switched on again.

 Determine

whether

deenergized.

 Ground and short-circuit.

 Cover or block off adjacent

energized parts.

WARNING

Danger due to gauge pressure
and vacuum!

Danger due to escaping fluid!

Before beginning work on the
unit or system:
 Interrupt supply of operating

liquid.

 Bleed lines and vacuum

pump/compressor
(depressurize).

CAUTION

Incorrect connection of the motor
can lead to serious damage to
the unit!



Observe the motor rating plate.
It is imperative that the operating conditions
correspond to the data given on the rating
plate!

Deviations permissible without reduction in
performance:

 ±5 % voltage deviation

 ±2 % frequency deviation


Make the connection in accordance with the
circuit diagram in the terminal box.
Connect the protective conductor.

 Use suitable cable lugs when doing so.

 The electrical connection must be

permanently safe.

 Tightening torques for terminal plate

connections:

Thread

M4 M5

[Nm]

0.8 ... 1.2 1.8 ... 2.5

Tightening
torque

[ft lbs]

0.590 ...

0.885

1.33 ...

1.84

WARNING

Electrical danger!

Clearance between bare live
parts and between bare live parts
and ground:

at least 5.5 mm [0.217"] (at a
nominal voltage of V

n

≤ 690V)

Make sure there are no
protruding pieces of wire!