Danger, Warning – Elmo Rietschle L-BV7 User Manual

Page 29

Advertising
background image


© Gardner Denver Deutschland GmbH

29 / 64

610.48060.40.000

Commissioning

Check connections of the pipes/hoses for
leaks.

Check direction of rotation:

 The direction of flow of the pumped

gases/vapors is marked with arrows on the
intake and discharge connection.

 The intended direction of shaft rotation is

marked with an arrow on the motor
mounting adapter between the intake and
discharge connection, as well as with an
arrow on the fan guard.

 The pump-motor unit may not be allowed to

run dry!
Have you filled it with operating liquid
beforehand (during or after installation)?

See sections "Fill with operating liquid",
Pg. 26 and Pg. 28.

 Briefly switch on pump-motor unit.

 Compare the actual direction of rotation of

the external fan with the intended direction
of shaft rotation as indicated with the
arrows.

 Switch off pump-motor unit again.

 If necessary, reverse the direction of

rotation of the motor.

DANGER

Electrical danger!

The electrical connection may be
carried out by trained and
authorized electricians only!

DANGER

Electrical danger!

Before beginning work on the
unit or system, the following
measures must be carried out:
 Deenergize.

 Secure against being

switched on again.

 Determine

whether

deenergized.

 Ground and short-circuit.

 Cover or block off adjacent

energized parts.

WARNING

Danger due to gauge pressure
and vacuum!

Danger due to escaping fluid!

Before beginning work on the
unit or system:
 Interrupt supply of operating

liquid.

 Bleed lines and vacuum

pump/compressor
(depressurize).



The further procedure is again dependent