13 accessories – Elmo Rietschle L-BV7 User Manual

Page 44

Advertising
background image


610.48060.40.000

44 / 64

© Gardner Denver Deutschland GmbH

Accessories

13 Accessories

13.1 Flanges

The pipes on the intake and discharge side are
connected to intake and discharge connections
via the flanges.

See Fig. 17, Pg. 44.

2BV7 06: G1
2BV7 07: G1½

2BV7 06: 30 Nm (22.13 ft lb)
2BV7 07: 50 Nm (36.88 ft lb)

Fig. 17: Flanges



Mounting

The flanges are mounted when connecting the
pipes/hoses, as described in Chapter 7.3,
"Connecting pipes/hoses (vacuum
pump/compressor)", Pg. 25.

Proceed as follows:

 Screwing flanges onto intake and discharge

connections.
Use commercially available liquid sealant
(e.g. Loctite) when doing so.
Tightening torque: dependent on the
sealant.

 Screw intake and discharge connections

onto flanges.
Use commercially available liquid sealant
(e.g. Loctite) when doing so.
Tightening torque: dependent on the
sealant.

13.2 Non-return

valve

The non-return valve is basically a valve with a
plate seat. Its function is to prevent the
pumped gases/vapors as well as the operating
liquid from flowing back out of the pump in
case the operation of the pump-motor unit is
interrupted. It is mounted on the inlet
connection of the unit for this purpose.

See Fig. 18, Pg. 44.

2BV7 06: G1
2BV7 07: G1½

Fig. 18: Non-return valve



Mounting

The non-return valve is mounted when
connecting the pipes/hoses, as described in
Chapter 7.3, "Connecting pipes/hoses
(vacuum pump/compressor)", Pg. 25.

Proceed as follows:

 Screw on the non-return valve with the

arrow pointing downward on the inlet
connection.
Use commercially available liquid sealant
(e.g. Loctite) when doing so.
Tightening torque: dependent on the
sealant.

 Screw the inlet pipe onto the non-return

valve.
Use commercially available liquid sealant
(e.g. Loctite) when doing so.
Tightening torque: dependent on the
sealant.


Advertising