11.2 Repairs/troubleshooting

Fault

Cause

Remedy

Carried out by

Motor does
not start,
no motor
noise.

At least two
power supply
leads interrupted.

Check fuses, terminals and cables for open
circuit. Eliminate open circuit.

Electrician

One power
supply lead
interrupted.

Check fuses, terminals and cables for open
circuit. Eliminate open circuit.

Electrician

Free shaft by turning.
See Chapter 11.1, "Maintenance", Pg. 36.

Operator

Decalcify vacuum pump/compressor.
See Chapter 11.1, "Maintenance", Pg. 36.

Operator

Drain and clean vacuum pump/compressor if
necessary.
See Chapter 11.1, "Maintenance", Pg. 36.

Operator

Impeller is
jammed.

Check and correct impeller gap setting if
necessary.

Service

Impeller
defective.

Replace impeller.

Service

Motor does
not start,
humming
noise..

Motor bearings
defective.

Replace motor bearings.

Service

Winding short-
circuit.

Have winding checked.

Electrician

Motor
overloaded.

Throttle operating-liquid flow rate.
See Chapter 8.2, "Self-priming operation", Pg. 30
or 8.3, "Operation with operating-liquid feed",
Pg. 31.

Operator

Counter-pressure
at discharge
connection too
high.

Reduce counter-pressure.

Operator

Share of liquid
also fed too high.

Reduce share of liquid also fed.

Operator

Protective
motor switch
trips when
motor is
switched on.

Impeller is
jammed.

See "Motor does not start,
humming noise."

Service

Decalcify vacuum pump/compressor.
See Chapter 11.1, "Maintenance", Pg. 36.

Operator

Power
consumption
too high.

Lime or other
deposits.

Clean vacuum pump/compressor.
See Chapter 11.1, "Maintenance", Pg. 36.

Operator

No operating
liquid.

Ensure proper operating-liquid flow rate.
See Chapter 8.2, "Self-priming operation", Pg. 30
or Chapter 8.3, "Operation with operating-liquid
feed", Pg. 31.

Operator

Severe leak in the
system.

Seal leak in the system.

Operator

Unit does not
generate
vacuum.

Wrong direction
of rotation.

Reverse direction of rotation by interchanging two
connecting leads.

Electrician