ABUS TVCC75200 User Manual

Page 51

Advertising
background image

51



1. Alarm:

4 Alarm inputs

2. AUX:

DC 12 V with up to 1 A can be used at the AUX terminal.
Possible applications using AUX are e.g. turning on a light or remote control.

3. TX:

TX transmits data signal received from RX to other equipment.
TX is convenient terminal for daisy chain connection.

4. RX:

RX receives control signal from controller or DVR.

5. Video out: BNC connector (1Vp-p)
6. Power:

AC 24 V 1.0 A adaptor
* Do not connect power supply to the middle screw of the power terminal.
Middle screw is for grounding only.

7. Power ON LED