4. TOUR SET – PRESET NO.


Connect with tour step #1 ~60; it is possible to select any preset no. from 1 to 64 and 100 to
200. The default setting is BLK for blank, which means tour step is not assigned to any
preset number.

5. TOUR SET – DWELL TIME

Each Tour step has its own dwell time from 01 second up to 99 seconds.
The default setting is 03 seconds.

6. TOUR SET – SPEED

Motional speed can be separately set for each tour step. Auto scan speed can be adjusted
from 10° per second up to 300° per second. Move joystick to the right or left to select tour
speed.
The default setting is 300°/S.

7. TOUR SET – SAVE


To save the memorized data, move joystick rightwards when cursor is at SAVE. The cursor
will automatically move to the next tour step then.

8. TOUR SET – EXIT


Move joystick to the right to return to main menu.

8.7 Privacy Set


24 Privacy masking zones make it easy to block out confidential areas (e.g. keyboard entries) and
will be shown as blue squares.










1. PRIVACY SET – PRIVACY NO.


Up to 24 privacy masking zones (TVCC75200) respectively 4 (TVCC75100) are available.

2. PRIVACY SET – DISPLAY


Move joystick to the right or left to switch on the selectable block in the central of the monitor.
This block is appearing as a translucency square with blue colour after set ON. The default
setting is OFF.




PRIVACY SET

PRIVACY NO : 01
DISPLAY :

OFF

ACTION :

MOVE

SAVE
EXIT

DEFAULT SETTING