Selecting presets, 1 _ operating the timed program – B&K Precision 1696-1698 - Manual User Manual

Page 15

Advertising
background image

15

go to the next Preset.


Whenever you want to determine Preset Programming you can press the CLEAR key to return to normal operation mode.


Selecting Presets

1. Press the RECALL key

The display will show Recall_

2. Press the number key (1-9).

The display will show the chosen Preset Number, its voltage and current level.

3. Press ENTER to activate .The unit will resume the chosen reset values.

If during any of the above procedures, you fail to input a setting within 10 seconds, the unit will cancel the procedure and resume the previous

settings. You can exit any of the above operations by pressing the CLEAR key and the unit will resume to its previous settings.

7.1 _ Operating the Timed Program

The unit can be programmed to operate up to 20 timed subprograms (1-19 STEP as shown in the display). Each subprogram is capable of running a

preset operation period of 1 second to 99 minutes and 99 seconds with its own preset voltage and cur

r

ent level. The timed subprogram can be set to run

in sequence repeatedly from 1 to 232 cycles. You can run the unit through the sequence of sub programs for the input cycles number unless interrupted
by pressing the CLEAR key.

Programming the Unit

1.

Press the PROG key

2.

Press the 0 key (to get to the Timed Program Mode) and the display will show Program 0 StEP-..00

3.

Input subprogram number 0 to 19 and press ENTER to confirm.

4.

Input voltage level followed by ENTER to confirm and the display will show I-set.

5.

Input current followed by ENTER to confirm. The bottom left corner of the display will show Timer00m00s

and the appearing minute symbol m.

6.

Input minute period (0-99) followed by ENTER to confirm. The bottom left corner of the display will show Timer00m00s

and the appearing

second symbol s

.

7.

Input seconds period (0-99) followed by ENTER to confirm. The timed subprogram will automatically to next subprogram number ready input of
new settings.

8.

Repeat procedure 4 to 7.