4 operation instruction for rs-485 interface, 1 configuration of each power supply – B&K Precision 1696-1698 - Manual User Manual

Page 29

Advertising
background image

29

4.

Data exceeding the rated voltage and current will not be accepted.

5.

Voltage exceeding set UVL (upper output voltage limit) will not be accepted.

6.

If retrieved or entered data exceeds upper or lower limit, setting of voltage, current, time the date will become red in color.

7.

Transfer set data to power supply by clicking [Save to PS].

8.

Click [Read Fro PS] to initiate the [run] command.

9.

Set number of desired [[running cycle] and click [run].

Internal Preset Memory

The operation principle is the same as Internal Timed Program
To activate the selected preset, click on the box of the [Select] column then click Run.

If retrieved or entered data exceed present Upper or Lower limit setting of voltage/current/time, the data becomes red in color.

9.4 Operation Instruction for RS-485 Interface

This interface operation is provided for remote access/control up to 31 power supplies. The setup procedures below:

9.4.1 Configuration of each Power Supply

1.

Make certain that your PC is OFF. Use RS-485 plug to connect the power supplies to each other.

2.

Check to see if the PC’s are interconnected. Use RS-485 to RS-232 converter to connect power supplies and the serial com port of
your PC (Fig. 4.).