Basic Operation

37

coarse is selected, the vertical scale knob changes the

channel scale in a 1-2-5 step sequence.

Channel Keys CH1, CH2

Press the channel key from the front panel to display the

channel’s menu and turn the display of the channel on or off.

The channel is displayed when the key is illuminated.

The channel menu of a channel must be displayed first

before you can turn off the channel. For example, suppose

CH1 and CH2 are both displayed and the CH2 menu is also

displayed. In order to turn CH1 off, you should press the CH1

key first to show CH1 menu on the display, then press CH1

key again to turn off CH1.

CH1, CH2 Menu

Press the channel key CH2 to display the channel’s menu

and turn on the channel display.

Channel Coupling

Press the channel key CH2, then press the Coupling softkey

to select AC coupling mode.

AC coupling places a high pass filter in series with the input

signal that blocks the DC component of the input signal. AC

coupling is useful for viewing waveforms with large DC

offsets.