Installation and connection, On period d.c.f. formulas, Definitions – DE-STA-CO F5-B AC Inverter Drive User Manual

Page 25

Advertising
background image

25

On period
d.c.f.

Formulas

4. Braking time with braking resistor

Valid range: n

1

> n

N

(field weakening)

Conditions: T

B

- 1.5 • T

N

f < 1.4 x rated frequency of motor

Conditions:

P

B

< P

R

Valid range:

n

1

> n

N

f < 1.4 x rated frequency of motor
P

B

< P

R

3. Peak braking power

1. Braking time without braking
resistor

2. Braking torque (required)

(J

M

+ J

L

) • (n

1

- n

2

)

T

B

=

- T

L

(307 • t

B)

T

B

• n

1

P

B

=

7.04

(J

M

+ J

L

) • (n

1

- n

2

)

t

Bmin

=

307 • (K • T

N

+ T

L

)

t

f

t

B

t

Z

ON period d.c.f for cycle
time t

Z

> 120 s

ON period d.c.f for cycle
time t

Z

< 120 s

Definitions

(J

M

+ J

L

) • (n

1

- n

2

)

t

Bmin

=

307 • K• T

N

+ T

L

+

( )

(P

R

• 7.04)

(n

1

- n

2

)

P

R

• 9.55

Conditions:

- T

N

• (1.5 -K)

(n

1

- n

2

)

t

B

d.c.f =

• 100 %

t

Z

t

B

d.c.f =

• 100 %

120 s

K = 0.25 for motors up to 2 hp
0.20 for motors

3 to 5 hp

0.15 for motors

7.5 to15 hp

0.08 for motors

20 to 60 hp

0.05 for motors

75 to 400 hp

J

M

= Moment of inertia of the motor [lb ft

2

]

J

L

= Moment of inertia of the load [lb ft

2

]

n

1

= Motor speed before deceleration [rpm]

n

2

= Motor speed after deceleration [rpm]

(Stand still = 0 rpm)

n

N

= Motor rated speed [rpm]

T

N

= Motor rated torque [ft lbs]

T

B

= Braking torque (required) [ft lbs]

T

L

= Load torque [ft lbs]

t

B

= Braking time (required) [s]

t

Bmin

= Minimum braking time

[s]

t

Z

= Cycle time

[s]

P

B

= Peak braking power

[W]

P

R

= Peak power dissipation of the resistor [W]

Installation and Connection

Advertising