3 digital inputs, 4 analog inputs, 5 analog output – DE-STA-CO F5-B AC Inverter Drive User Manual

Page 27: 6 relay outputs, Installation and connection, 5 analog output 3.5.4 analog inputs

Advertising
background image

27

Installation and Connection

Internal analog
speed ref. setting

External analog
speed ref. setting

3.5.5 Analog

Output

3.5.4 Analog

Inputs

1

10 11 14 15

GND

16

20 22

X2A

1

10 11 14

GND

15 16

22

+

X2A

3.5.3 Digital

Inputs

In case of inductive load on the relay output, protective wiring must be
provided (e.g. free-wheeling diode)!

1

7 8

R = 3...10 kW

GND

5

22

X2A

1 5

8

22

GND

7

X2A

+

0(4)...20 mADC

Ri = 250 W

0...±10 VDC

Ri = 30 kW

+

1

22

5 7 8

GND

+10 VDC / 5 mA

X2A

3.5.6 Relay

Outputs

Rin = 2.1 kΩ

Use of external voltage supply

Use of internal voltage supply

20...30 VDC Regulated

optional:

24 25 26

GND

27 28 29

max.30VDC/1A

+

-

X2A

Advertising