1. General

AC motor controls, depending on their degree of protection,
may have exposed live, un-insulated, and possibly also mov-
ing or rotating parts, as well as hot surfaces.

Removal of the protective covers, improper use, improper in-
stallation or operation, can be dangerous and result in serious
personal injury and or damage to property.

This document must be read in its entirety before attempting to
apply voltage to the KEB COMBIVERT F5.

All functions of, installation and commissioning as well as
maintenance are to be carried out by skilled or certified techni-
cal personnel (Observe IEC 364 or CENELEC HD 384 or DIN
VDE 0100 and IEC 664 or DIN/VDE 0110, NEC and all na-
tional and local codes and accident prevention rules!).

For the purposes of these basic safety instructions, ”skilled tech-
nical personnel“ means persons who are familiar with the in-
stallation, mounting, commissioning and operation of the prod-
uct and have the qualifications needed for the performance of
their functions.

2. Intended use

AC motor controls are components designed for installation and
operation in electrical installations or machinery.

In case of installation in machinery, commissioning of the drive
converter (i.e. the starting of normal operation) is prohibited
until the machinery has been proved to conform to the provi-
sions of the directive 89/392/EEC (Machinery Safety Directive
- MSD). Account is to be taken of EN 60204.

Commissioning (i.e. the starting of normal operation) is admis-
sible only where conformity with the EMC directive (89/336/
EEC) has been established. The KEB COMBIVERT F5 motor
controls meet the requirements of the low-voltage directive 73/
23/EEC. They are subject to the harmonized standards of the
series DIN EN 50178/VDE 0160 in conjunction with EN 60439-
1/ VDE 0660, part 500, and EN 60146/ VDE 0558.

The technical data as well as information concerning the sup-
ply conditions shall be taken from the name plate and from the
documentation and shall be strictly observed.

3. Transport, storage

The instructions for transport, storage and proper use shall be
complied with.

The climatic conditions shall be in conformity with EN 50178.

Safety and operating instructions for

AC motor controls

(in conformity with the low-voltage directive 73/23/EEC)

Important, please read

1. Safety and Operating Instructions

4. Installation

The installation and cooling of the unit shall be in accordance
with the specifications contained with in this document.

The unit shall be protected against excessive force or strain. In
particular, no components must be bent or isolating distances
altered in the course of transportation or handling. No contact
shall be made with electronic components and contacts.

Drive converters contain electrostatic sensitive components
which are can be damaged through improper use or handling.
Electric components must not be mechanically damaged or
destroyed (potential health risks).

5. Electrical connection

RISK OF ELECTRIC SHOCK! Always disconnect the supply
voltage before installing or servicing the KEB COMBIVERT F5
motor control! Wait five minutes for the before attempting to
change any connections as the internal DC bus must first dis-
charge.

If it is necessary to work with the voltage supply turned on,
always comply with the applicable national accident prevention
rules (ex O.S.H.A.).

The electrical installation shall be carried out in accordance
with the relevant requirements (NEC and local codes). For fur-
ther information, see documentation.

Instructions for installation in accordance with EMC require-
ments, like shielding, grounding, location of filters and wiring,
are included in the documentation. They must always be com-
plied with. Motor controls bearing a CE marking do not pre-
clude adherence to proper EMC installation requirements. Ob-
servance of the allowed values required by EMC law is the
responsibility of the designer or manufacturer of the installa-
tion or machine.

6. Operation

Installations which include motor controls shall be equipped
with additional control and protective devices in accordance
with the relevant applicable safety requirements. Changes to
the motor control by means of the operating software are ad-
missible.

After disconnection of the motor control from the supply volt-
age, live parts and power terminals must not be touched be-
cause DC BUS capacitors may still be energized. Always fol-
low the printed warnings on the unit.

During operation, all covers and doors shall be kept closed.

7. Maintenance and servicing

The manufacturer’s documentation shall be followed.

KEEP SAFETY INSTRUCTIONS IN A SAFE PLACE!